RRML - Basophil activation test versus radio-immunoassay in the diagnosis of β-lactam immediate-type hypersensitivity reactions
AMLR

ISSN online: 2284-5623

ISSN-L: 1841-6624

Rejection rate (2020): 75%

Română English


Journal Metrics

Impact Factor 0.5
Five Year Impact Factor 0.5
JCI 0.12


Advanced search


Top 10 downloaded articles
- April 2024 -
 
A comprehensive review of Prof... 24
Recomandarea comună EFLM-COLA... 13
Monocyte to high-density lipop... 9
Anti-thyroid peroxidase (TPO) ... 9
Understanding the key differen... 7
Understanding the pathogenesis... 7
Function of the S1P pathway in... 6
Predictive value of expression... 5
The importance of tumor marker... 4
Romanian Review of Laboratory ... 4

Log in

Concept, Design & Programming
Dr. Adrian Man

   
 
Nr. 21(4)/2013 DOI:10.2478/rrlm-2013-0044
XML
TXT

Basophil activation test versus radio-immunoassay in the diagnosis of β-lactam immediate-type hypersensitivity reactions

Cristina Petrişor, Nadia Gherman-Ionică, Ramona Bologa, Manuela Sfichi, Natalia Hagău


Abstract:

Background and aims: to assess the sensitivity and specificity for the basophil activation test (BAT) and the detection of drug-specific antibodies (IgE) in the retrospective diagnosis of β-lactam allergy by using assay-specific thresholds as resulted from the performance of receiver operating characteristics curve (ROC) analysis and to describe a sequential algorithm that might increase diagnostic sensitivity and reduce the number of patients that should undergo drug challenge tests by the joint use of in vivo and in vitro diagnostic tests. Meth- ods: 37 patients with suspected β-lactam immediate-type hypersensitivity reactions were tested for the culprit drug. 31 healthy controls were similarly tested. BAT was performed with Flow2Cast technique (Bühlmann Laboratories, Switzerland). Drug-specific IgE antibodies were detected using “sandwich”-type radio-immunoassay (RIA) with sepharose as solid phase (Pathologie Université „H. Poincare”, France). Results: ROC curve analysis identifies an optimal threshold>1.9 for RIA positivity, with 70.3% sensitivity and 90.3% specificity. For BAT, an optimal threshold>1.97 yields 51.4% sensitivity and 90.3% specificity. 89.18% of the patients were diagnosed by the combined use of skin tests and in vitro tests results, while 10.82% of the patients had negative tests results. Conclusions: RIA seems to have higher sensitivity than BAT (70.3% versus 51.4%) for β-lactams. The joint use of allergy diagnostic tests has 89.18% sensitivity. A combination of allergologic skin tests, detection of antibiotic– specific antibodies, followed by BAT may be suitable for investigating β-lactam hypersensitivity reactions since no diagnostic test has absolute diagnostic accuracy.

Keywords: drug allergy,antibiotic,flow cytometry,basophil activation test

 
  PDF Download full text PDF
(236 KB)
  PDF Supplementary material
     
 
How to cite
Petrişor C, Gherman-Ionică N, Bologa R, Sfichi M, Hagău N. Basophil activation test versus radio-immunoassay in the diagnosis of β-lactam immediate-type hypersensitivity reactions. Rev Romana Med Lab. 2013;21(4):415-22. DOI:10.2478/rrlm-2013-0044